Through-the-Wall Wine Cellar Cooling Unit for Enclosed Cellars Up to 265 cu. ft.
The Breezaire WKCE 2200 is a self-contained, through-the-wall wine cellar cooling unit designed for fully enclosed, insulated wine cellars up to 265 cubic feet.
It delivers 2200 BTU of cooling power and operates on a standard 115V outlet, making it a practical solution for residential wine rooms that do not require a split system.
This unit is designed for enclosed cellars only. It is not intended for open rooms, glass-heavy enclosures, or oversized spaces.
Also available in Breezaire WKCE 1060 offers reliable cooling for wine cabinets with precision climate control for optimal wine storage.
Is the WKCE 2200 Right for Your Cellar?
Choose This Unit If:
- Your cellar is 150–265 cu. ft.
- The room is fully insulated and vapor sealed
- You can provide rear ventilation
- You want a single-piece through-the-wall system
- You have access to a 115V / 60Hz outlet
Do NOT Choose This Unit If:
- The cellar exceeds 265 cu. ft.
- The room has excessive glass or poor insulation
- Exhaust air cannot be properly ventilated
- The cellar is located in a noise-sensitive living area
- You require a remote condenser (consider WKSL split systems)
Correct sizing and ventilation determine performance and longevity.
Cooling Performance Overview
- Cooling Output: 2200 BTU
- Capacity Rating: Up to 265 cubic feet
- Humidity Control: Automatic retention within sealed cellar
- Defrost System: Automatic
- Control Type: Electronic with digital display
Unlike standard air conditioners, the WKCE 2200 is engineered specifically for wine storage. It is designed for stable, long-term operation in insulated environments.
Capacity Fit Guide
| Cellar Size | Fit Assessment |
|---|---|
| Under 150 cu. ft. | Oversized |
| 150–265 cu. ft. | Ideal |
| Over 265 cu. ft. | Undersized |
If your cellar includes heavy glass, high ambient heat, or marginal insulation, a cooling load calculation is recommended before purchase.
Installation Requirements
Installation Type: Through-the-Wall
System Type: Self-Contained
Exhaust Direction: Rear
The unit installs directly through an interior wall separating the cellar from a ventilated adjacent space.
Rear Ventilation Rules
The exhaust area must:
- Allow continuous airflow
- Prevent heat buildup
- Remain unsealed
Do NOT vent into:
- Sealed wall cavities
- Small enclosed closets
- Unventilated attics
- Exterior walls without protection
Improper ventilation can cause overheating and reduce system lifespan.
Noise Expectations
As a self-contained system, the WKCE 2200 produces sound similar to a quiet window air conditioner.
Suitable for:
- Basement wine rooms
- Dedicated enclosed cellars
- Utility-adjacent spaces
For primary living areas or display rooms requiring quieter operation, a split system (WKSL series) is recommended.

Electrical Requirements
- Voltage: 115V
- Frequency: 60 Hz
- Current Draw: 4 Amps
Operates from a standard household outlet. Always follow local electrical codes.
Technical Specifications
| Specification | Detail |
|---|---|
| Cooling Capacity | Up to 265 cu. ft. |
| Cooling Output | 2200 BTU |
| Installation Type | Through-the-Wall |
| Exhaust Direction | Rear |
| Electronic Controls | Yes |
| Digital Temperature Display | Yes |
| High-Temperature Alarm | No |
| Humidity Control | Automatic |
| Defrost System | Automatic |
| Electrical | 115V / 60Hz |
| Electrical Draw | 4 Amps |
| Dimensions (H x W x D) | 10.50" x 18" x 16.50" |
| Weight | 55 lbs |
| Warranty | 1 Year Labor / 5 Years Parts |
Installation and User Manuals for Breezaire WKCE 2200
- WKCE 2200 Installation Manual
- Breezaire Sentry III Plus Controller Owner's Manual
- Breezaire Warranty
Important Limitations
- No built-in high-temperature alarm
- Must not be installed in oversized rooms
- Requires insulated, vapor-sealed construction
- Requires proper rear ventilation
- Not designed for open or hybrid room installations
Installation conditions directly impact warranty compliance and performance.

WKCE 2200 vs Split System (WKSL Series)
| Feature | WKCE 2200 | WKSL Split System |
|---|---|---|
| Installation | Through-the-Wall | Remote Condenser |
| Noise Inside Cellar | Moderate | Very Low |
| Installation Complexity | Simple | Professional Recommended |
| Best For | Enclosed utility-adjacent cellars | Living-area display cellars |
| Ventilation Requirement | Rear ventilation required | Condenser installed remotely |
Choose WKCE for simplicity.
Choose WKSL for quieter operation and flexible condenser placement.
Warranty Coverage
- Labor: 1 Year
- Parts: 5 Years
Applies under proper installation and operating conditions.

Summary
The Breezaire WKCE 2200 is a compact, 2200 BTU through-the-wall wine cellar cooling solution designed for insulated, enclosed wine rooms up to 265 cubic feet.
It provides electronic temperature control, automatic defrost, humidity retention, and operates from a standard 115V outlet.
Correct sizing, insulation, and ventilation are essential for reliable performance and warranty compliance.
Breezaire - Set & Adjust All Settings
Breezaire Sentry III Reset
Breezaire Set & Adjust Temperature
Breezaire Bottle Probe
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
📚 Frequently Asked Questions (FAQs)
No. This unit is rated for up to 265 cubic feet. Installing it in a larger space can result in insufficient cooling and compressor strain.
Only if the attic is properly ventilated and heat cannot accumulate. Venting into an enclosed or poorly ventilated attic can cause overheating and system failure.
It operates similarly to a quiet window air conditioner. For near-silent interior operation, a split system (WKSL series) is more appropriate.
It draws 4 amps at 115V. While it can operate on a standard outlet, electrical installation should follow local code requirements.
No. It automatically helps retain natural humidity in a sealed cellar but does not add moisture. Supplemental humidification may be required in dry climates.
Improper insulation increases cooling load and may prevent the unit from maintaining stable temperatures. Always ensure vapor barrier and insulation meet wine cellar standards."]