CellarCool CX4400 Wine Cellar Cooling Unit
CellarCool CX4400 Wine Cellar Cooling Unit - FRONT POWER CORD is backordered and will ship as soon as it is back in stock.
CellarCool CX4400 Wine Cellar Cooling Unit - FRONT POWER CORD is backordered and will ship as soon as it is back in stock.
In Stock & Ready to Ship
Estimated Delivery in 3-7 business days
Call Us At 1 (888) 885-1670 Or Chat Now To UNLOCK THE BEST PRICE AVAILABLE!
Description
Description
Is the CellarCool CX4400 Right for Your Wine Cellar?
The CellarCool CX4400 is a self-contained, through-the-wall wine cellar cooling system designed for fully insulated and sealed wine rooms up to 1,000 cubic feet under ideal construction conditions.
It is engineered to maintain a 55°F cellar temperature when:
- The cellar is properly insulated
- A continuous vapor barrier is installed
- The condenser intake air does not exceed 85°F
- A dedicated 115V / 20 amp circuit is provided
- Rear exhaust air can dissipate freely
If any of these conditions are not met, cooling performance will decrease.
Reminder: The CellarCool CX Series Wine Cooling Unit CX4400 requires the area it is releasing or exhausting its hot air doesn't exceed 85°F for your wine cellar to be at 55°F.
Available in CX2200 for 265 cu.ft wine cellar, CX3300 for 650 cu.ft wine cellar, CX4400 for 1000 cu.ft wine cellar, CX8800 for 2000 cu.ft wine cellar
Quick Fit Summary
| Criteria | Requirement |
|---|---|
| Maximum Rated Cellar Size | 1,000 cu. ft. |
| Installation Type | Through-the-wall, partially ducted |
| Voltage | 115V |
| Dedicated Circuit | 20 amp required |
| Running Amps | 9 amps |
| Intake Air Limit | 85°F maximum |
| Noise Level | 63–64 dBA |
| Drain Line | 3/8” rear condensate |
| Warranty | 2-year parts & labor / 5-year compressor |
Cooling Performance
Rated Capacity
- Up to 1,000 cubic feet
- Assumes fully insulated and sealed enclosure with proper vapor barrier
Cooling Output
- BTUh (with 85°F condenser intake air): 2,962 BTUh
- Horsepower: 1.16 HP
- Airflow: 216 CFM
Temperature Delta
The CX4400 can maintain a 55°F cellar temperature when condenser intake air remains at or below 85°F.
If intake air exceeds 85°F:
- Cooling efficiency declines
- Compressor strain increases
- Temperature stability may fluctuate
This unit is not designed for high-ambient mechanical rooms or enclosed exhaust spaces.
Noise Level
| Component | Sound Rating |
|---|---|
| Evaporator | 63 dBA |
| Condenser | 64 dBA |
This sound output is typical for self-contained through-the-wall systems.
For installations in noise-sensitive areas (living spaces, glass display walls), a split system with a remote condenser may be more appropriate.
Electrical Requirements
- Voltage Rating: 115V
- Dedicated Circuit: 20 amp required
- Running Amps: 9 amps
Failure to provide a dedicated 20 amp circuit may result in:
- Breaker tripping
- Electrical overheating
- Compressor damage
- Warranty issues
Always verify panel capacity before installation.
Installation Requirements
Installation Type
-
Through-the-wall
-
Supports partial ducting configurations
Condenser Ventilation
Rear exhaust must:
- Discharge into a ventilated space
- Not recycle hot air
- Not be enclosed without ventilation
Improper exhaust ventilation is a common cause of overheating and premature failure.
Drainage
- 3/8” rear condensate line
- Must be routed properly to avoid backflow
Construction Requirements
To achieve rated performance, the cellar must include:
- Minimum R-19 wall insulation (or equivalent)
- Insulated ceiling
- Continuous vapor barrier on warm side
- Airtight, sealed door
- No shared HVAC air exchange
This unit is not intended for open basements or unfinished rooms.
Physical Dimensions & Weight
| Measurement | Specification |
|---|---|
| Width | 14.25” |
| Height | 19.75” |
| Depth | 21.63” |
| Weight | 67 lbs |
Confirm wall framing dimensions before cutting.
Refrigerant & Controls
- Refrigerant: R-134a
- Thermostat: Advanced digital display
The digital controller provides stable temperature regulation for wine storage environments.
Manuals for CellarCool CX4400
Warranty Coverage
- 2-Year Parts & Labor Warranty
- 5-Year Compressor Warranty
Warranty applies when installation meets manufacturer guidelines.
Professional installation is recommended.
Who Should Choose the CX4400?
Choose This Unit If:
- Your cellar is under 1,000 cu. ft.
- Construction includes proper insulation and vapor barrier
- Intake air remains below 85°F
- You have a 20 amp dedicated circuit available
- Rear ventilation space is adequate
Do Not Choose This Unit If:
- The room exceeds rated volume
- The space lacks a vapor barrier
- Exhaust air cannot dissipate freely
- Ambient intake temperatures exceed 85°F
- You require ultra-quiet operation
- The cellar includes large uninsulated glass surfaces
In those cases, a higher-capacity or split system may be required.
Final Decision Summary
The CellarCool CX4400 is a self-contained cooling solution for wine cellars up to 1,000 cubic feet when construction and installation requirements are met.
Before purchasing, confirm:
- Total cubic footage
- Insulation quality
- Vapor barrier integrity
- Dedicated 20 amp circuit availability
- Rear exhaust ventilation space
- Intake air remains under 85°F
If these conditions cannot be met, this unit may not perform as rated.
The Ultimate Commercial Wine Cooling Solutions
Expert Tips on Building a Wine Cellar with CellarCool
CellarCool’s New Smart Controller Technology Explained
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
📚 Frequently Asked Questions (FAQs)
It is rated for cellars up to 1,000 cubic feet in a fully insulated and sealed environment. Larger spaces or poorly insulated rooms will reduce effective cooling capacity.
The unit is rated to maintain 55°F with intake air up to 85°F. Above that threshold, cooling efficiency decreases and compressor stress increases.
Yes. A 115V / 20 amp dedicated circuit is required. The unit draws approximately 9 running amps.
No. It is designed only for sealed, insulated wine cellars with proper vapor barrier installation.
It operates at approximately 63–64 dBA, typical for through-the-wall self-contained systems.
It supports partial ducting. Full ducting configurations must follow manufacturer installation guidelines to avoid airflow restriction."]