Written by Jim Hopper, Wine Cooling Expert · Updated September 2026
How Do I Reset My Wine Cellar Cooler? The Quick Answer
For most units, a reset means turning the power off, waiting a few minutes and turning it back on, then letting the built-in restart delay pass. Some controllers also have a documented reset. On a Breezaire Sentry III, for example, you press and hold the WARMER button for at least 5 seconds.
A reset only clears the symptom. If a safety switch or alarm stopped the unit, find and fix the cause first, or the unit will stop again.
In short: note any code on the display, fix the obvious cause (dirty condenser, blocked exhaust, door left open), then reset the way your manual describes. Breezaire, WhisperKOOL and Wine Guardian each handle resets differently, and Wine Guardian's high pressure switch resets differently by unit type. If the same code returns after a reset, stop resetting and call a licensed technician.
When Resetting a Wine Cooling Unit Helps
A reset is worth trying when the unit has stopped after a power interruption, when the display is frozen or showing an alarm you have already dealt with, or when a protection feature shut the unit down and you have removed the cause.
A reset does not fix a dirty condenser coil, a leaky cellar, a failed fan or a refrigerant problem. Resetting over and over without fixing the cause can hide a fault until it becomes expensive. If your cellar is simply warm, start with our guide to a wine cellar that is not cooling. If the unit keeps stopping on its own, read why wine coolers switch off repeatedly.
Before You Reset: Safety Checks
- Write down any code or alarm on the display before you touch anything. It tells a technician what happened.
- Check the breaker and outlet. A tripped breaker that trips again is an electrical problem for a professional.
- Look at the condenser side for lint, dust or anything blocking the warm-air exhaust.
- Do not open electrical or refrigerant compartments unless you are qualified. Wine Guardian's manuals state that only qualified personnel should perform maintenance.
- Remember that a controller set to OFF is not a power disconnect. Wine Guardian notes that high voltage is still present at the main control board when the remote interface is off.
How to Do a General Power Reset
- Turn the unit off at its switch or controller, then disconnect power at the plug or breaker.
- Wait several minutes so the controls fully power down.
- Fix what you can see: clean the condenser coil, clear the exhaust, close the cellar door.
- Restore power and turn the unit back on.
- Allow the restart delay. Cooling units wait before restarting the compressor to protect it, so the fan may run or the unit may stay quiet for a few minutes. The length of the delay depends on your model.
- Watch the first cycle. Confirm cold air is coming out and no code returns.
How Reset Differs by Brand
Reset behavior in the manufacturer documentation
| Item | Breezaire (Sentry III) | Wine Guardian | WhisperKOOL |
|---|---|---|---|
| Controller reset | Hold WARMER for at least 5 seconds | No single reset button for all settings; settings are restored one by one | No separate reset procedure documented; alarm codes stay until the cause is corrected |
| Factory defaults | Hold WARMER and COOLER together for more than 5 seconds; display shows "Fr" | Each setting is changed back individually | See your controller manual |
| Safety shutdown | Blocked-airflow and over-heat protection | High pressure switch; reset method depends on unit type | Condenser over-temperature alarm (COH on SC units) |
| Settings after power loss | Retained in memory | See your unit manual | See your controller manual |
How to Reset a Breezaire Sentry III Controller

The Sentry III owner's manual documents two procedures.
Manual reset: press and hold the WARMER button for at least 5 seconds. The display briefly shows "8.8.", then the software version, then the temperature unit, then the storage temperature. The manual notes that all user settings are kept after a manual reset. If the unit had not been off for long, it will wait before restarting.
Return to factory defaults: hold the WARMER and COOLER buttons together for more than 5 seconds. The display shows "Fr". The factory storage setting is 55°F.
The manual also states that the controller keeps its settings through a power interruption of any length, so there is no need to re-program it after an outage. The WKL manual adds that the Sentry III has no "off" position and begins to run within minutes of being plugged in.
A Sentry III may flash "E1" if it detects insufficient cooling during start-up, or "OH" after an over-heat shutdown. The manual lists a manual reset among the ways to restart after these; if the same shutdown repeats, it tells you to contact your Breezaire dealer. See every documented Sentry III display code in our guide to wine cooling unit error codes.
Watch a Sentry III reset
A short walk-through of resetting the Breezaire Sentry III controller on a wine cellar cooling unit.
- Where the WARMER button is
- What the display shows during reset
- Returning to normal operation
Resetting a Wine Guardian Unit and Its High Pressure Switch
Remote interface controller. Wine Guardian states that there is no reset button that returns all settings to factory default; each setting is changed individually. The On/Off button has a 5-minute delay before the system turns off.
High pressure switch. This safety switch stops the compressor and condenser when refrigerant pressure is too high. Wine Guardian names restricted condenser airflow, such as a dusty filter or a blocked duct or grille, as the most common cause. On the remote interface this shows as "!1", which stays on screen until the switch is reset.

High pressure switch reset by unit type
| Unit type | Switch type | What the manual says to do |
|---|---|---|
| Ducted self-contained | Manual reset | Remove the obstruction or clean the filter, switch the unit off, open the access panel, grille or duct collar at the condenser, press the reset button on the switch near the compressor, then restart |
| Through-the-wall | Automatic reset | The unit restarts on its own after the pressure drops and a time delay passes. If the switch trips four times in less than one hour, an alarm requires a manual alarm reset from the Alarms menu, and the troubleshooting table says to contact a service technician |
| Split systems | Varies | Follow the manual for your specific split model and have a qualified technician perform the work |
Resetting the high pressure switch
A short demonstration of the high pressure switch reset on a Wine Guardian system, performed after the root cause has been identified and corrected.
- Intended for qualified service work
- Correct restricted airflow first
- Repeated trips mean a deeper fault
Clearing Alarms on a WhisperKOOL Unit
WhisperKOOL's SC Series manual does not describe a separate reset procedure. When the unit needs attention it shows an alarm symbol and sounds a buzzer. Pressing any button silences the buzzer, but the alarm code stays on the display until the cause is corrected. To view the code, press and release the set button, then press and release it again while "AL" is displayed.
The most common SC alarm related to heat is "COH", which means the condenser coil is too hot. The manual's fixes are to clean the condenser coil, make sure intake air does not exceed 85°F, and confirm both condenser fans work. The unit resumes normal operation once the condenser has cooled. On Platinum Split units the display must be unlocked by holding any button for one second before other buttons work.
For split systems, keep the warranty in mind: WhisperKOOL requires installation by a certified HVAC/R technician and a completed warranty checklist to activate coverage.
If the Unit Still Does Not Work After a Reset
- Same code returns: the cause is still there. Look the code up for your controller and call a technician if it is a sensor, pressure or compressor fault.
- Unit runs but the cellar stays warm: the problem is capacity or the room, not the controller. Check the condenser, exhaust space and air leaks.
- Breaker trips on restart: stop and call a licensed electrician or HVAC professional.
- Water on the floor: see why a wine cooling unit leaks water.
- Unit is old and failing repeatedly: compare repair and replacement in our guide on when to replace a cellar cooling unit.

Wine Cooling Expert, Wine Cellar Authority
A reset is a diagnostic step, not a repair. If a unit needs resetting once after a storm, fine. If it needs resetting every week, something is making it shut down, and that is what you should be paying someone to find.
For every other symptom, from noise to ice, use our complete wine cellar troubleshooting guide.
Replacement Controllers and Sensors
If a technician confirms a failed controller or sensor, order the exact part for your model. Browse Breezaire controllers and replacement parts or Wine Guardian remote interfaces and sensors, and use our guide to matching a replacement part to your unit. If the unit itself has reached the end of its life, compare current wine cellar cooling units.
Real questions owners ask before and after resetting a wine cooler or cellar cooling unit. Tap any question to expand the answer.
How do I reset my wine cellar cooler?
Turn the unit off, disconnect power for several minutes, fix any obvious cause such as a dirty condenser or blocked exhaust, then restore power and allow the restart delay. If your controller has its own reset procedure, follow the manual.
How do I reset a Breezaire Sentry III controller?
Press and hold the WARMER button for at least 5 seconds. The display shows 8.8., the software version and then the temperature. The Sentry III manual states that user settings are kept after a manual reset.
How do I restore factory settings on a Breezaire wine cooling unit?
On the Sentry III controller, hold the WARMER and COOLER buttons together for more than 5 seconds until the display shows Fr. The factory storage temperature setting is 55°F.
How do I reset the high pressure switch on a Wine Guardian unit?
It depends on the unit type. Ducted self-contained units have a manual reset button on the switch near the compressor. Through-the-wall units reset automatically, but four trips in under an hour trigger an alarm that needs a manual alarm reset and a service technician. Always correct the cause first.
Why won't my wine cooler turn back on after a reset?
Most units wait before restarting the compressor to protect it, so give it a few minutes. If it still does not start, check the breaker, look for a code on the display, and call a technician if the same fault returns.
Does resetting a wine cooler erase the settings?
Not usually. Breezaire's Sentry III keeps its settings after a manual reset and through power interruptions. Wine Guardian's remote interface has no single reset to factory defaults; each setting is changed individually.
How do I clear an alarm on a WhisperKOOL unit?
Press any button to silence the buzzer. The alarm code stays on the display until the cause is corrected. On SC units, press set, then press set again while AL is shown to see the code.
When should I stop resetting my wine cooling unit and call a technician?
Call a licensed HVAC professional if the same code or shutdown returns after you have cleaned the condenser and cleared the exhaust, if the breaker trips, or if the unit runs without producing cold air.
Reset Did Not Solve It?
Send us your model and the code on the display, and our team will help you find the right part or a replacement unit.
This guidance is general and based on published manufacturer documentation. Procedures differ by model; always follow the manual for your unit. Electrical, refrigerant and compressor work must be performed by a licensed HVAC professional.