A vapor barrier is missing or improperly installed
The room includes extensive uninsulated glass
The space exceeds 1,750 cubic feet without engineering verification
You require fully concealed cooling (consider a ducted split model instead)
Improper sizing is the most common cause of cooling failure. A professional heat load calculation is strongly recommended before purchase.
How the Platinum Split 8000 Ductless System Works
This is a split-system wine cellar cooling unit, meaning:
The evaporator is installed inside or adjacent to the cellar.
The condenser is installed remotely (attic, mechanical room, or outdoors).
The evaporator delivers cooled air directly into the cellar through a visible grille. Heat is removed through refrigerant lines to the condenser, which may be installed up to 100 line feet away.
This separation reduces noise and heat transfer inside the cellar while allowing flexible installation.
Cooling Performance & Capacity
Cooling output varies depending on condenser air intake temperature. As ambient temperature increases, total BTU output decreases.
Performance by Condenser Intake Temperature
Condenser Air Intake
Sensible BTU/h
Total BTU/h
60°F
4,641 – 5,415
4,834 – 5,521
75°F
4,427 – 4,839
4,580 – 4,969
85°F
4,322 – 4,798
4,479 – 4,879
Important: These values assume a fully insulated and sealed cellar with proper vapor barrier construction.
Temperature Capability
Designed to maintain a 55°F cellar temperature
Operates in environments with condenser intake temperatures up to 120°F
Performance depends on insulation quality and construction
Installation Requirements
Electrical Requirements
Evaporator
120V
15-amp dedicated circuit required
Running Amps: 2.2
Condenser (220V High Efficiency)
220V
15-amp dedicated circuit required
LRA: 13.2
RLA: 3.19
FLA: 2.66
Professional HVAC-R installation is required. Failure to use a qualified technician may void the manufacturer warranty.
Line Set & Distance Limits
Condenser may be installed up to 100 line feet from evaporator
Evaporator may be installed up to 25 duct feet from cellar
Drain line: 1/2” ID tubing (not included)
Improper line length, poor airflow, or undersized electrical supply can affect performance.
Key System Features
Advanced Digital Touch Display
50-ft cable
Built-in system protection alarms
Monitors operating parameters
Liquid Temperature Bottle Probe
Measures the temperature of the wine liquid rather than just ambient air, improving temperature accuracy and protecting long-term aging.
220V High-Efficiency Condenser
Designed for improved electrical performance in larger residential applications.
Two-Speed Fan Control
Allows adjustment of cooling output based on environmental demand.
Optional 24V Thermostat Conversion Kit
Allows integration with customer-supplied smart thermostats
Enables remote monitoring and alerts
Replaces the standard WhisperKOOL controller and bottle probe
WhisperKOOL does not supply smart thermostats
Noise Level
42–46 dBA depending on fan speed Quiet enough for residential installations when properly mounted.
Refrigerant
R-134a
Dimensions & Weight
Evaporator
22.1” L x 22.5” W x 15.5” H
Weight: 56 lbs
Condenser
21.18” L x 10.75” W x 21.18” H
Manuals for WhisperKOOL Platinum Split 8000 Ductless:
Choosing the correct cooling system is critical to protecting your wine collection. If you are unsure whether the Platinum Split 8000 is appropriate for your project, our cooling specialists can review your cellar specifications and assist with proper sizing.
WhisperKOOL
WhisperKOOL Platinum Split 8000 Ductless Cooling System 220V High Efficiency
Regular price$7,995.00 USD
Unit price
Is the Platinum Split 8000 Right for Your Wine Cellar?
The WhisperKOOL Platinum Split 8000 (220V High Efficiency) is designed for wine cellars up to approximately 1,750 cubic feet when the space is:
Fully insulated
Sealed with a proper vapor barrier
Professionally heat-load calculated
Built to standard wine cellar construction practices
This system is ideal when you need:
A ductless evaporator inside the cellar
A remotely located condenser (up to 100 line feet away)
Improved energy efficiency compared to 110V models
Quiet operation with flexible installation options
If your cellar meets these conditions, this model is often an appropriate mid-to-large residential solution.
A vapor barrier is missing or improperly installed
The room includes extensive uninsulated glass
The space exceeds 1,750 cubic feet without engineering verification
You require fully concealed cooling (consider a ducted split model instead)
Improper sizing is the most common cause of cooling failure. A professional heat load calculation is strongly recommended before purchase.
How the Platinum Split 8000 Ductless System Works
This is a split-system wine cellar cooling unit, meaning:
The evaporator is installed inside or adjacent to the cellar.
The condenser is installed remotely (attic, mechanical room, or outdoors).
The evaporator delivers cooled air directly into the cellar through a visible grille. Heat is removed through refrigerant lines to the condenser, which may be installed up to 100 line feet away.
This separation reduces noise and heat transfer inside the cellar while allowing flexible installation.
Cooling Performance & Capacity
Cooling output varies depending on condenser air intake temperature. As ambient temperature increases, total BTU output decreases.
Performance by Condenser Intake Temperature
Condenser Air Intake
Sensible BTU/h
Total BTU/h
60°F
4,641 – 5,415
4,834 – 5,521
75°F
4,427 – 4,839
4,580 – 4,969
85°F
4,322 – 4,798
4,479 – 4,879
Important: These values assume a fully insulated and sealed cellar with proper vapor barrier construction.
Temperature Capability
Designed to maintain a 55°F cellar temperature
Operates in environments with condenser intake temperatures up to 120°F
Performance depends on insulation quality and construction
Installation Requirements
Electrical Requirements
Evaporator
120V
15-amp dedicated circuit required
Running Amps: 2.2
Condenser (220V High Efficiency)
220V
15-amp dedicated circuit required
LRA: 13.2
RLA: 3.19
FLA: 2.66
Professional HVAC-R installation is required. Failure to use a qualified technician may void the manufacturer warranty.
Line Set & Distance Limits
Condenser may be installed up to 100 line feet from evaporator
Evaporator may be installed up to 25 duct feet from cellar
Drain line: 1/2” ID tubing (not included)
Improper line length, poor airflow, or undersized electrical supply can affect performance.
Key System Features
Advanced Digital Touch Display
50-ft cable
Built-in system protection alarms
Monitors operating parameters
Liquid Temperature Bottle Probe
Measures the temperature of the wine liquid rather than just ambient air, improving temperature accuracy and protecting long-term aging.
220V High-Efficiency Condenser
Designed for improved electrical performance in larger residential applications.
Two-Speed Fan Control
Allows adjustment of cooling output based on environmental demand.
Optional 24V Thermostat Conversion Kit
Allows integration with customer-supplied smart thermostats
Enables remote monitoring and alerts
Replaces the standard WhisperKOOL controller and bottle probe
WhisperKOOL does not supply smart thermostats
Noise Level
42–46 dBA depending on fan speed Quiet enough for residential installations when properly mounted.
Refrigerant
R-134a
Dimensions & Weight
Evaporator
22.1” L x 22.5” W x 15.5” H
Weight: 56 lbs
Condenser
21.18” L x 10.75” W x 21.18” H
Manuals for WhisperKOOL Platinum Split 8000 Ductless: